Ammonia is composed of Nitrogen and Hydrogen and at room temperature, it is a colourless gas and an irritant with a pungent odour. It’s one of the most common industrial chemicals and is both very toxic and flammable with an LEL of 16%. Ammonia is highly irritating to the eyes, skin, and respiratory system. It can cause burning sensations, coughing, and difficulty breathing. Inhalation of high concentrations can lead to lung damage, chemical burns, and even fatality.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, do eiusmod ut labore et dolore magna aliqua.

Chlorine Dioxide is a popular water treatment solution in various industries. It has great disinfectant and oxidising qualities making it highly effective in water treatment. However, with this gas comes its dangers as it is highly toxic, making it a potential hazard for these industries. Implementing ClO₂ gas monitors is an efficient and effective way to mitigate these hazards.

Do you use ClO2 in your industry? Do you know the dangers of this gas?

ClO₂ Applications

Water treatment is essential in a wide variety of industries for a range of purposes. Chlorine dioxide is highly effective and safe to use for the purpose of treating drinking water to make it fit for purpose. ClO2 is also widely used in hospitality and leisure applications, such as in hotels for disinfecting swimming pools and hot tubs, as well as for keeping water parks clean. Other applications include:

  • Food and Beverage production
  • Environmental Hygiene
  • Cooling towers
  • Wastewater
  • Effluent treatment

One of the reasons it is preferred over other disinfectants in these applications is because it is only needed in small doses to work effectively. Additionally, ClO2 does not react with organic materials to form Trihalomethanes (THMs), unlike Chlorine, thus making it massively beneficial in the creation of drinking water. ClO2 effectively controls microbiological growth and biofilms in industrial cooling waters, making it favourable over other disinfectants such as Chlorine.

Due to its reactivity, Chlorine Dioxide photolyzes rapidly in the atmosphere and will breakdown in natural water quickly. Thus, although it is naturally environmentally hazardous, it will not last long in nature. All of these benefits make Chlorine Dioxide massively beneficial in water treatment, and therefore is often chosen over other water treatment solutions. But naturally, with its benefits also come the hazards, requiring the implementation of a Chlorine Dioxide gas monitor.

 

The Hazards of ClO2

Chlorine Dioxide is a highly toxic gas at room temperature. It can be identified with its reddish-yellow colour and its pungent, chlorine-like odour. If a leak occurs, personnel within the vicinity can quickly become overexposed to this substance, as the STEL is as low as 0.3ppm. Overexposure can cause irritation to the eyes, nose, throat and lungs, with severe cases causing chronic bronchitis and pulmonary edema. Due to the extensive hazards attached to this gas, it is vital that personnel are equipped with the proper mitigation devices, such as Chlorine Dioxide gas monitors.

 

Mitigating the Hazard with Chlorine Dioxide Gas Monitors

International Gas Detectors have been manufacturing gas detection equipment for over 100 years, giving us the expertise and experience to provide detectably better Chlorine Dioxide gas monitors.

TOC-750 Safe Area Detector

The TOC-750 Safe Area detector is a versatile and advanced solution. Utilising IGD’s ground-breaking 2-Wire addressable technology, both power and communication are provided over a 2-core cable highway. Saving 70% on installation in comparison to similar models on the market. The TOC-750 detector features a unique sensor labyrinth design and can be fitted with splash guards. So, it is perfectly suited for water treatment applications, as accidental water splashes will not affect the sensor’s performance.

mPower UNI Portable Gas Detector

The UNI portable Chlorine Dioxide gas monitor is one of the latest additions in our portable portfolio. This device offers lightweight, durable and flexible ClO2 personal gas detection, ensuring that gas safety is hassle-free and comfortable for your team. The UNI from mPower is easy to use and easy to service. As many as 50 event logs can be saved onto the device itself, with easy transferability to any PC via the docking station. Find out more about the UNI chlorine dioxide gas monitor here.

Contact IGD Today

IGD provide a wide range of both fixed and portable gas detection, fit for purpose for various applications. To find out more about our range, contact the team today.

Our experts have vast experience in a range of industries, including water treatment. So, you are guaranteed to be getting the best advice available straight from the experts.

Related Products

TOC-903-X5 Transmisor Detector de Gas Dual

Detector de Gas Direccionable para Áreas Seguras TOC-750

Detector de gas portátil BELLMINI

The SafePark Detector

Related Press

Why You Need A Gas Detection Control Panel
A gas detection system is only as effective as the control panel behind it. This article explores why a dedicated ...
The Importance of Regular Gas Detector Maintenance
All gas detection systems require regular maintenance to ensure optimal operation and operational accuracy. Your gas detection system needs to ...
Electric Vehicle Fires: Hydrogen Fluoride Risks and the Role of Gas Detection
Electric vehicles may be kinder to the environment, but the complications and dangers presented by electric vehicle fires pose a ...
Gas Detection in Latin America: A Year on the Ground with Lorena Monroy
Join Lorena Monroy as we embark on a gas detection journey across Latin America, building partnerships, showcasing our tech and ...

Send Us A Message

We are deeply committed to delivering unparalleled service and unwavering support to ensure your experience exceeds expectations.

Let’s Start Something New,
Say Hello!
UK & Ireland:
Location

Triton House, Crosby St, Stockport, SK2 6SH

Contact
Contact

Mon - Fri: 08:30 - 18:00

Closed at weekends